Eaton FlexPDU & HotSwap MBP
Designed for reliable and cost-effective power distribution.

9130 with FlexPDU

ePDU Models
ePDU, 1U, Basic, input C20, output (12) C13, (1) C19
#EFLXI3000R-PDU1UIEC
List Price: $203.00
Our Price: $152.00
ePDU, 1U, Basic, input 5-15P, output (12) 5-15R, (1) C19
#EFLXL1500R-PDU1U
List Price: $123.00
Our Price: $92.00
ePDU, 1U, Basic, input 5-20P, output (12) 5-20R
#EFLXL2000R-PDU1U
List Price: $134.00
Our Price: $101.00
ePDU, 1U, Basic, input 5-20P, output (5) L5-20R
#EFLXL2000R-PDU1UL
List Price: $175.00
Our Price: $131.00
ePDU, 1U, Basic, input 5-15P, output (6) 5-15R
#EHBPL1500R-PDU1U
List Price: $296.00
Our Price: $222.00
ePDU, 1U, Basic, input 5-20P, output (6) 5-20R
#EHBPL2000R-PDU1U
List Price: $354.00
Our Price: $266.00
ePDU, 1U, Basic, input L5-30P, output (5) 5-20R
#EHBPL3000R-PDU1U
List Price: $540.00
Our Price: $423.00

Overview:

Eaton provides five different functions for rack power distribution solutions. Two of these functions, FlexPDU and Maintenances Bypass PDU, were created as accessories specific to some of our UPSs. Both of these units offer the flexibility of connections to meet the demanding requirements of today's data center architects.

The HotSwap Maintenance Bypass (MBP) unit enables easy UPS replacement without interruption of the load. The HotSwap MBP is ideal when exchanging a unit or servicing a UPS. For added convenience, the HotSwap MBP offers two types of receptacles: 5-15R or 5-20R. The FlexPDU is a basic function power distribution unit with a short power cord for easy, close mounting. FlexPDUs are available with 5-15R, 5-20R or L5-20R output receptacles, for connection to a wide range of equipment.

Both of these options allow for easy deployment, even in space-constrained environments. You have a variety of mounting options, including top and side mounting.

Features

  • HotSwap MBP provides service continuity during UPS maintenance or upgrade
  • Both units offer connections to all types of equipment
  • Eases installation with flexible mounting options
  • Minimal depth accommodates most space constraints

FlexPDU

FlexPDUs:

Eaton FlexPDUs increase power distribution from a single UPS.

  • 3 foot cord allows easy connection close to UPS without cable clutter
  • Mounting bracket attaches directly to UPS
  • Mounting bracket allows for vertical, 1U or UPS attachment
Catalog NumberInput PlugBreakerMax kWFunctionCord
(ft)
OrientationReceptaclesDimensions
(H x W x D, in)
EFLX1500R-PDU1U5-15PNone1.44BA31U(12) 5-15R (1) C191.7 x 17.3 x 2.3
EFLX2000R-PDU1U5-20PNone1.92BA31U(12) 5-20R1.7 x 17.3 x 2.3
EFLX2000R-PDU1UL5-20PNone1.92BA31U(5) L5-20R2.0 x 17.3 x 3.0
EFLXI3000R-PDU1UIECC20 Inlet(2) 20A3.33BA31U(12) C13 (1) C191.7 x 17.3 x 2.3

FlexPDU

Hot Swap Maintenance Bypass:

Hot Swap MBPs enable easy UPS replacement without interruption to the connected load. Placing the HotSwap MBP in bypass mode provides utility power to equipment while the UPS is being serviced.

Catalog NumberInput PlugBreakerMax kWFunctionCord(ft)OrientationReceptaclesDimensions(H x W x D in)
EHBPL1500R-PDU1U5-15PNone1.44BA82U(6) 5-15R2.1 x 17.3 x 3.8
EHBPL2000R-PDU1U5-20PNone1.92BA82U(6) 5-15R2.1 x 17.3 x 3.8
EHBPL3000R-PDU1UL5-30P(2) 20A2.88BA3.32U(5) 5-20R2.1 x 17.3 x 3.8

Hot Swap Maintenance Bypass

Specifications:

Product Snapshot
Power Range1.44kW to 3.33 kW
Input Voltage100 to 240 V
FunctionBasic (BA)

ePDU Models
Part NumberStyle NumberFunctionInput PlugOutput Receptacles
EFLXI3000R-PDU1UIEC68438BAC20(12) C13, (1) C19
EFLXL1500R-PDU1U58015BA5-15P(12) 5-15R, (1) C19
EFLXL2000R-PDU1U58020BA5-20P(12) 5-20R
EFLXL2000R-PDU1UL58021BA5-20P(5) L5-20R
EHBPL1500R-PDU1U58115BA5-15P(6) 5-15R
EHBPL2000R-PDU1U58120BA5-20P(6) 5-20R
EHBPL3000R-PDU1U58130BAL5-30P(5) 5-20R

Documentation:

Download the ePDU Data Center Catalog(PDF).

Download the Eaton Flex and Hotswap MBP ePDU Brochure Nov 2011(PDF).